Quantcast
Viewing all articles
Browse latest Browse all 22625

ADuCM36x Analog Input Channels

Hi sir,

I have one doubt about the ADC single ended channel configuration in ADuCM361 controller.

In that we have channels from AIN0-AIN11 then if we want to configure them in the single ended we will get normally 12 single ended channels with AGND as the common reference.But in User Manual they mentioned that only 11 single ended channels are available.what is reason for that? Actually we have tested AIN0 and AIN11 channel by giving voltage across AIN0 and AGND,AIN11 and AGND.

Please help me to solve this problem.

 

with regardss,

P. Hima Bindu


Viewing all articles
Browse latest Browse all 22625

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>