This is an odd question.
I have a customer that designed a board using the AD7656-1. His proto boards were accidentally populated with the AD7656. He understands that he has insufficient decoupling. However, so far, the A/D seems to be functioning properly with one problem. The reference voltage is wrong. It is at 2.27V not the expected 2.5V. On the scope, the reference is very clean, but is not at the correct level. The reference is lightly loaded.