Re: DC/DC design using ADP1046

$
0
0

With a 2/3 turns ratio (N1/N2) the output on the secondary of the transformer will by 13.5V at 9V input. The ADP1046A will still function as a DC DC providing the appropriate duty cycle that will step down 13.5V down to 12V which is 89%. If you want you can change the ratio so that the duty cycle is more like 60-75%.