Re: Problem with ADV7513 setting

$
0
0

We dont have a HDMI analyzer for testing the output. The format of data input to ADV7313 is in SMPTE(SMPTE 274M for 1080i50) instead of CEA-861, i.e, HSYNC is horizontal blanking, VSYNC vertical blanking and DE is Field.

 

We have achieved to get video at ADV7611 in progressive format, but not in interlaced mode. with a monitor with a HDMI input, we have achieved to get video in interlaced mode.

 

How the field 1 and 2 is identified by the ADV7513? Is there any way to setting the ADV7513 for working with SMPTE at input?

Thanks.