Re: ADR421 output voltage hysteresis specification

$
0
0

Hi Tony,

 

The product owner of ADR421 said that output voltage hysteresis is test to specific temperature range and we don't have data on your  temperature range. However, I can say that the one stated on the datasheet can be the worst case value, it was cycled to the full temperature range of the device but it is just typical value, it can go above and below it.

 