Re: Testing at temperature

$
0
0

A quick update - today I run two tests, using different temperature cycle profiles.

 

Test 1)

Profile start 70°C -> 10°C -> 70°C:

AD9361 calibrated at 70°C ambient, running LTE20 profile 2Rx2Tx: CW 10MHz TX Attenuation -10dB.

Loopback Frequency spectrum observed with MAX HOLD, and BBPLL Lock in 0x5E:8. No unlock over entire range observed.

 

Test 2)

70°C -> 10°C -> 70°C -> 0°C -> 70°C:

During temperature maxima re-calibrate AD9361 (@ 70,0,10): No unlocks or other issues observed.

Other conditions like 1).


profile.jpg

profile_edit.jpg


May I ask about more details - what is the exact temperature profile I should use?

Please provide temperature calibration points and exact device configurations for each calibration point.