Dear Sir :
We are high interesting in AD9361 for now project, according to the application,
I want to configure digital interface of AD9361 as single port Full Duplex mode with CMOS level,
please refer to figure 5(see attched file page 2). the setting of registers as below
Register address 0x010 set as 0xC8
Register address 0x011 set as 0x00
Register address 0x012 set as 0x24
Thus AD9361 should be under 1T1R, SDR, FDD and single port.
The question is what is the timing relation between clock and data in transmit/receive interface?
I couldn’t find the relevant timing chart in data sheet, so I draw the timing chart of data and clock
as attched file page 3, is it correct ? If it is not correct, please show me the exact timing chart.
In these condition
Receive data path functional timing as attched file page 3
Transmit data path functional timing as attched file page 3
Thank You for your help.
Best Regards
Tom hsu